| Supplier | Mix ID | Grading | RAP % | AC Supplier | PG Binder | Street Classification | Min/Max Lift Thickness | Expiration Date | |
|---|---|---|---|---|---|---|---|---|---|
| Connell | 10150 | SX | 75 | 20 | Suncor | 64-22 | Residential All Lifts | 1.5" / 3" | 3/27/2026 | 
| Connell | 10250 | SX | 75 | 0 | Suncor | 64-22 | Residential All Lifts | 1.5" / 3" | 3/27/2026 | 
| Connell | 11050 | SX | 75 | 20 | Suncor | 64-28 (modified) | Arterial/Major Collector/Industrial/Commercial Top Lifts | 1.5" / 3" | 3/27/2026 | 
| Connell | 12050 | SX | 75 | 20 | Suncor | 58-28 | Residential/Minor Collector All Lifts Arterial Lower Lifts | 1.5" / 3" | 3/27/2026 | 
| Connell | 20150 | S | 75 | 20 | Suncor | 64-22 | Residential/Minor Collector All Lifts Arterial/Major Collector/Industrial/Commercial Lower Lifts | 2" / 4" | 3/27/2026 | 
| Connell | 20250 | S | 75 | 0 | Suncor | 64-22 | Residential/Minor Collector All Lifts 
                Arterial/Major Collector/Industrial/Commercial | 2" / 4" | 3/27/2026 | 
| Connell | 20350 | S | 75 | 20 | Suncor | 64-22 | Residential/Minor Collector All Lifts Arterial/Major Collector/Industrial/Commercial Lower Lifts | 2" / 4" | Expired | 
| Connell | 21050 | S | 75 | 20 | Suncor | 64-28 (modified) | Arterial/Major Collector/Industrial/Commercial Top Lifts | 2" / 4" | 3/27/2026 | 
| Connell | 22050 | S | 75 | 20 | Suncor | 58-28 | Residential/Minor Collector All Lifts Arterial Lower Lifts | 2" / 4" | 3/27/2026 | 
| Holcim | 13-800074 | SX | 75 | 20 | Suncor | 64-22 | Residential/Minor Collector All Lifts Arterial/Major Collector/Industrial/Commercial Lower Lifts | 2" / 4" | 8/19/2025 | 
| Holcim | 28-800081 | S | 75 | 20 | Suncor | 64-22 | Residential All Lifts | 1.5" / 3" | 8/19/2025 | 
| Martin Marietta | 1225-5588 | SX | 75 | 30 | Suncor | 58-28 | Residential/Minor Collector All Lifts Arterial Lower Lifts | 1.5" / 3" | Expired | 
| Martin Marietta | 1243-5462 | SX | 75 | 20 | Suncor | 64-22 | Residential All Lifts | 1.5" / 3" | 4/15/2026 | 
| Martin Marietta | 1243-5462 (Greeley) | SX | 75 | 20 | Suncor | 64-22 | Residential All Lifts | 1.5" / 3" | 4/15/2026 | 
| Martin Marietta | 1253-5473 (Including WMA mix) | SX | 75 | 20 | Suncor | 64-28 (modified) | Arterial/Major Collector/Industrial/Commercial Top Lifts | 1.5" / 3" | 4/15/2026 | 
| Martin Marietta | 1253-5473 (Greeley) (Including WMA mix) | SX | 75 | 20 | Suncor | 64-28 (modified) | Arterial/Major Collector/Industrial/Commercial Top Lifts | 1.5" / 3" | 4/15/2026 | 
| Martin Marietta | 2223-5492 | S | 75 | 20 | Suncor | 58-28 | Residential/Minor Collector All Lifts Arterial Lower Lifts | 2" / 4" | 4/15/2026 | 
| Martin Marietta | 2225-5589 | S | 75 | 30 | Suncor | 58-28 | Residential/Minor Collector All Lifts Arterial Lower Lifts | 2" / 4" | Expired | 
| Martin Marietta | 2243-5493 | S | 75 | 20 | Suncor | 64-22 | Residential/Minor Collector All Lifts Arterial Lower Lifts | 2" / 4" | 4/15/2026 | 
| Martin Marietta | 2243-5493 (Greeley) | S | 75 | 20 | Suncor | 64-22 | Residential/Minor Collector All Lifts Arterial Lower Lifts | 2" / 4" | 4/15/2026 | 
| Martin Marietta | 2253-5494 (Including WMA mix) | S | 75 | 20 | Suncor | 64-28 (modified) | Arterial/Major Collector/Industrial/Commercial Top Lifts | 2" / 4" | 4/15/2026 | 
| 
 | |||||||||
| Simon | 
 | SX | 75 | 20 | Ergon | 64-22 | Residential All Lifts | 1.5" / 3" | Expired | 
| Simon | 
 | S | 75 | 15 | Jebro | 64-22 | Residential All Lifts | 1.5" / 3" | Expired | 
Approved Concrete Mix Designs#
| Material Supplier | Mix ID | Strength | Age | Intended Use | Expiration Date | 
|---|---|---|---|---|---|
| Aggregate Industries | 9456023 | 4500 psi | 28 Days | As Required CDOT Class B/D/P | Expired | 
| Aggregate Industries | 9456741 | 4500 psi | 28 Days | CDOT Class P / 24 Hr High Early | 7/25/2025 | 
| Bestway Concrete | 4531495 | 4500 psi | 28 Days | CDOT Class B/D/P | Expired | 
| Bestway Concrete | 4531275 | 4500 psi | 28 Days | CDOT Class B/D/P Low Slump | Expired | 
| Burnco | 01CBU0A9F | 50-150 psi | 28 Days | CDOT CLSM | Trial in Review | 
| Burnco | 30VS11D6X | 4500 psi | 28 Days | 24 Hr High Early | 12/2/2026 | 
| Burnco | 30VS11P6W | 4500 psi | 28 Days | 12 Hr High Early | 12/2/2026 | 
| Burnco | 45C1C1C2C | 4500 psi | 28 Days | CDOT Class B/D/P Low Slump | 6/12/2026 | 
| Burnco | 45C1C1C4C | 4500 psi | 28 Days | CDOT Class B/D/P Handwork | 6/12/2026 | 
| Burnco | 45VN31C4G | 4500 psi | 28 Days | Light Pole Base | Expired | 
| Holcim | 6406150 | 4000 psi | 28 Days | Exterior Flat Work | 6/14/2026 | 
| Holcim | 6450100 | 4500 psi | 28 Days | Exterior Flat Work | 6/14/2026 | 
| Holcim | 6550800 | 5500 psi | 28 Days | Fast Set | 6/14/2026 | 
| Holcim | 7456120 | 4500 psi | 28 Days | Class D Hand | 6/14/2026 | 
| Holcim | 7456122 | 4500 psi | 28 Days | Class D Machine | 6/14/2026 | 
| Holcim | 9456741 | 4500 psi | 28 Days | High Early | 6/14/2026 | 
| Johnstown Ready Mix | 021 | Min. 50 psi | 28 Days | Flow Fill | 4/28/2027 | 
| Johnstown Ready Mix | 027 | 4000 psi | 28 Days | Exterior, C&G, Sidewalks, Etc. | Expired | 
| Johnstown Ready Mix | 072 | 5000 psi | 28 Days | Exterior Concrete | 4/28/2027 | 
| Johnstown Ready Mix | 072 (2% NCA) | 5000 psi | 28 Days | 24 Hr High Early | 4/28/2027 | 
| Johnstown Ready Mix | 076 | 4500 psi | 28 Days | CDOT Class B & D | 4/28/2027 | 
| Johnstown Ready Mix | 076 (2% NCA) | 4500 psi | 28 Days | 48 Hr High Early | 4/28/2027 | 
| Johnstown Ready Mix | 076-F | 4500 psi | 28 Days | Class D | 4/28/2027 | 
| Johnstown Ready Mix | 076-CF | 4500 psi | 28 Days | Class D | 4/28/2027 | 
| Loveland Ready Mix | 021 | Min. 50 psi | 28 Days | Flow Fill | 4/28/2027 | 
| Loveland Ready Mix | 027 | 4000 psi | 28 Days | Exterior, C&G, Sidewalks, Etc. | Expired | 
| Loveland Ready Mix | 072 | 5000 psi | 28 Days | Exterior Concrete | 4/28/2027 | 
| Loveland Ready Mix | 072 (2% NCA) | 5000 psi | 28 Days | 24 Hr High Early | 4/28/2027 | 
| Loveland Ready Mix | 076 | 4500 psi | 28 Days | CDOT Class B & D | 4/28/2027 | 
| Loveland Ready Mix | 076 (2% NCA) | 4500 psi | 28 Days | 48 Hr High Early | 4/28/2027 | 
| Loveland Ready Mix | 076-F | 4500 psi | 28 Days | Class D | 4/28/2027 | 
| Loveland Ready Mix | 076-CF | 4500 psi | 28 Days | Class D | 4/28/2027 | 
| MMM | HE5224 | 5000 psi | 24 Hours | 24 Hr High Early | Expired | 
| Mustang Mobile Mix | COMM100FF22425 | 100 psi | 28 Days | Flow Fill | Trial in Review | 
| On-Demand | CDFF100R (Not Allowed Under Traffic Areas) | 100 psi | 28 Days | Flow Fill | 4/9/2027 | 
| On-Demand | CDFF175P | 100 psi | 28 Days | Flow Fill | 4/9/2027 | 
| On-Demand | CBDP4500R | 4500 psi | 28 Days | CDOT Class B/D/P | 6/22/2025 | 
| On-Demand | CDP4504C | 4500 psi | 4 Hours | CDOT Class D/P | In Trial | 
| On-Demand | CDP4504R | 4500 psi | 4 Hours | CDOT Class D/P | In Trial | 
| On-Demand | CBDP4524R | 4500 psi | 24 Hours | CDOT Class B/D/P High Early | 4/9/2027 | 
| On-Demand | FF160R (Not Allowed Under Traffic Areas) | 100 psi | 28 Days | Flow Fill | 4/9/2027 | 
| On-Demand | QSCAP2500 | 2500 psi | 4 Hours | Temporary Pavement Repair | 4/9/2027 | 
| On-Demand | QSFF080S | 50 psi | 28 Days | Flow Fill | Expired | 
| On-Demand | QSFF100S | 100 psi | 28 Days | Flow Fill | 4/9/2027 | 
| SRM Concrete | CDOT45070-3 | 4500 psi | 28 Days | CDOT Class B/D/P Hand Mix | Expired | 
| SRM Concrete | ZCDOT45070-3 | 4500 psi | 28 Days | CDOT Class B/D/P Hand Mix | Expired | 
| SRM Concrete | CDOT45071-3 | 4500 psi | 28 Days | CDOT Class B/D/P Machine Placement | Expired | 
| SRM Concrete | ZCDOT45071-3 | 4500 psi | 28 Days | CDOT Class B/D/P Machine Placement | Expired | 
| SRM Concrete | ZCDOT45878-3 | 4500 psi | 28 Days | CDOT Class B/D/P | 6/11/2027 | 
| SRM Concrete | 45050 | 4500 psi | 28 Days | Curb and Sidewalks | 3/25/2027 | 
| SRM Concrete | 45060 | 4500 psi | 28 Days | Curb and Sidewalks Machine Placement | 3/25/2027 | 
| SRM Concrete | 45260 | 4500 psi | 28 Days | Machine Placement | 3/28/2027 | 
| SRM Concrete | 45262 | 4500 psi | 28 Days | Hand Curb Mix | 3/28/2027 | 
| SRM Concrete | 45321 | 4500 psi | 24 Hours | 24 Hr High Early | Expired | 
| SRM Concrete | 45850 | 4500 psi | 28 Days | General Exterior | 6/11/2027 | 
| SRM Concrete | CDOT45888-3 | 4500 psi | 28 Days | 24 Hr High Early | 11/27/2026 | 
| SRM Concrete | 927 | 100 psi | 28 Days | Flow Fill | In Review |