Website home about our city

Fort Collins Utilities Home Efficiency Program Rebates
(Also shows Xcel program)

This matrix summarizes information regarding Home Efficiency Program rebates for improving homes in Fort Collins. If you need additional clarification, please call Fort Collins Utilities at 970-221-6700.

Some improvements may also qualify for other program rebates. For information on these rebates programs use the following hyperlinks:

Consult those program sponsors for details.

General Notes Regarding Eligibility

  • Rebates are available for improvements to existing, single-family homes – single-family detached homes, duplexes, tri-plexes, and four-plexes – with individual heating systems. Other types of housing are not eligible to participate in this program.
  • Rebates can be used for improvements to owner-occupied and rental properties receiving electric service from Fort Collins Utilities.
  • A Fort Collins Efficiency Audit is required as a prerequisite before efficiency improvement measures are installed.
  • Improvements must be installed by contractors included on the applicable Fort Collins Utilities Participating Contractor List . As these lists will be periodically updated, be sure the version you're using is current. Homeowner installations do not qualify for rebates.
  • Improvements must be installed in accordance with the details of the Home Efficiency Program Installation Standards. This is the contractor's responsibility. Key aspects of the Installation Standards are shown below as “Requirements.”
Home Efficiency Program Rebates
Efficiency
Measure
Requirements
and Options
Rebate Amounts for
Gas-heated Homes
Rebate Amounts for
Electric-heated Homes
Air Sealing
  • Existing condition: All except tight houses are eligible ( >ACH50 of 3.0)
  • Minimum leakage reduction of 25% must be achieved.
  • Combustion safety test required after sealing is completed.
Rebate amount varies with % reduction in house shell leakage:
  • Tier 1, 25% - $200
  • Tier 2, 33% - $300
  • Tier 3, 50% - $400
Rebate amount varies with % reduction in house shell leakage:
  • Tier 1, 25% - $300
  • Tier 2, 33% - $400
  • Tier 3, 50% - $500
Conditioned
Crawl Space
Insulation
  • Existing condition: un-insulated or poorly installed insulation.
  • Existing moisture problems must be mitigated.
  • Moisture barrier must seal onto foundation wall
  • Seal all crawl space vents to exterior.
  • Rim joist: apply foam board or spray foam, R-10 minimum, air seal
  • Foundation wall – options:
  • Insulate on interior with  unfaced or perforated-face fiberglass batts or blanket, R-19 minimum
  • Insulate on interior with closed cell foam board or spray foam, R-10 minimum
  • Insulate on exterior with foam board, R-10 minimum; down to top of footing. Protect above grade.
Rim joist
  • Spray foam -
    $1.00/sf, max $500
  • Foam board -
    $0.50/sf, max $300
      Foundation wall
  • Fiberglass (interior) -
    $0.30/sf, max $250
  • Spray foam (interior) -
    $0.50/sf, max $300
  • Foam board (interior or exterior) -
    $0.50/sf, max $300
Rim joist
  • Spray foam -
    $1.50/sf, max $750
  • Foam board -
    $0.75/sf, max $450
      Foundation wall
  • Fiberglass (interior) -
    $0.45/sf, max $375
  • Spray foam (interior) -
    $0.75/sf, max $450
  • Foam board (interior or exterior) -
    $0.75/sf, max $450
Cold
Crawl Space Insulation
  • Call Fort Collins Utilities for approval before proceeding with improvement
  • Moisture barrier must seal onto foundation wall
  • Fill floor joist cavity w/ insulation
  • Air barrier installed on bottom of joist cavity
$0.30/sf, max $250 $0.45/sf, max $375
Efficiency
Measure
Home Efficiency Program Rebates Rebate Amounts for
Gas-heated Homes
Rebate Amounts for
Electric-heated Homes
Basement Wall Insulation
  • Existing condition: Basement walls insulated to R-3 or less.
  • Existing moisture problems must be mitigated.
  • Rim joist: apply closed cell foam board or spray foam, R-10 minimum; air seal
  • Foundation wall insulation– Options:
  • On interior with unfaced fiberglass batts, R-13 minimum, inside finished frame wall.
  • On interior with unfaced fiberglass batts in finished frame wall, R-13 minimum, plus 1” foam board on foundation.
  • On interior with spray foam or foam board, R-10 minimum.
  • On exterior with foam board, R-10 minimum, 48” below-grade; cover above-grade.
Rim joist
  • Spray foam -
    $1.00/sf, max $500
  • Foam board -
    $0.50/sf, max $300
Foundation wall
  • Fiberglass batt (interior) -
    $0.30/sf, max $250
  • Fiberglass batt + foam board (interior) - $0.80/sf, max $550
  • Spray foam or foam board (interior) - $0.50/ sf, max $300
  • Foam board (exterior) -
    $0.50/sf, max $300
Rim joist
  • Spray foam -
    $1.50/sf, max $750
  • Foam board -
    $0.75/sf, max $450
Foundation wall
  • Fiberglass batt (interior) -
    $0.45/sf, max $450
  • Fiberglass batt + foam board (interior) - $1.20/sf, max $900
  • Spray foam or foam (interior) - $0.75/ sf, max $450)
  • Foam board (exterior) -
    $0.75/sf, max $450
Cantilever Floor Insulation

No restriction on existing condition; block interior end of joist cavity & dense pack; air seal exterior and interior.

$0.50/ sf ,
max of $200
$.75/ sf,
max of $300
Floor
Over Garage Insulation

Existing insulation R-11 or <; Joist cavity must be end blocked and air sealed. Remove/replace garage ceiling drywall to code before insulating, if water pipes in floor.

$0.50/ sf ,
max of $200
$.75/ sf,
max of $300
Exterior Frame
Wall Insulation

Existing: R-9 or <; must air seal all wall assembly openings (windows, doors & electrical boxes) prior to dense packing walls; completely fill all stud cavities.

$0.50/s.f. (net wall area), max of $500   $.75/s.f. (net wall area), max of $750
Masonry Exterior Wall Insulation

Existing: un-insulated;
Exterior Wall: R-10 foam board covered with appropriate finish.
Interior Wall: R-10 foam board or spray foam; R-13 batt or blown cellulose in finished frame wall.

$0.50/s.f. (net wall area), max of $500   $.75/s.f. (net wall area), max of $750
Attic Insulation
(Flat Ceiling)

No minimum existing insulation level. Must air seal interior ceiling/ attic interface. Add a minimum R-25 blown insulation on top of disturbed insulation in attic. Must insulate and air seal thermal by-passes, knee walls & skylights. Must repair duct problems in attic before insulating.

 

$0.30/s.f. of flat attic area + knee wall area, max $500   $0.45/s.f. of flat attic area + knee wall area, max $750
Efficiency
Measure
Home Efficiency Program Rebates Rebate Amounts for
Gas-heated Homes
Rebate Amounts for
Electric-heated Homes
Cathedral Ceiling Insulation.

No minimum existing insulation.
Roof cannot be leaking, or need replacement.
Rafter cavity must be dense packed with cellulose or short fiber fiberglass insulation.

$0.50/s.f.,
max of $500  
$.75/s.f.,
max of $750
Window and/or Sliding Glass Door Replacement

Existing windows and sliding glass doors must be single pane; clear glass; or metal framed. Exterior walls and existing window frames left in place must be insulated and air sealed.
Windows and sliding glass doors must be Energy Star qualified for our northern climate, w/ a low maintenance exterior.

$2.50/s.f., max $750   $3.75/s.f., max $1,000
Window Film

Call for pre-approval.
Existing windows must be unshaded E, S, or W, with clear glass.
Professional install required.
Films must meet Energy Star qualifying guidelines.

$1.50/s.f.,
max $300
$1.50/s.f.,
max $300
Replacement Air Handler Blower Motor

Existing motor is PSC.
New motor must be brushless DC.
Match new airflow to old airflow.

$150 $150
Replacement Gas Furnace

Existing furnace is < 83% AFUE.  Furnaces must be sized with approved method & commissioned.
Must be sealed combustion with intake & exhaust to outside.
Tier 2 furnace must have modulating gas valve & ECM motor

2 Tiers of rebates based on furnace efficiency:
Tier 1: 90 % min AFUE - $300 Tier 2: 92 %min AFUE - $500
N/A
Replacement Gas Boiler

Call for pre-approval. Existing hydronic system must be evaluated by Efficiency Plus Audit or HEP Participating Hydronic Specialty Contractor.

85% or > efficiency boiler - $300 N/A
New Installation AC

A/C system must be sized with approved method; condensing and evaporator units must be matched. Proper installation verified w/ CheckMe commissioning test.

 

 

 

 

2 Tiers of efficiency rebates:
SEER14, EER 12 - $250 SEER 15, EER 12.5 - $350
2 Tiers of efficiency rebates:
SEER14, EER 12 - $250 SEER 15, EER 12.5 - $350
Efficiency
Measure
Home Efficiency Program Rebates Rebate Amounts for
Gas-heated Homes
Rebate Amounts for
Electric-heated Homes
Early Replacement A/C

A/C must be working. Contractor does initial CheckMe tune-up; system qualifies for early replacement if operating EER is < 8. New A/C system must be sized with approved method; condensing and evaporator units must be matched. Proper installation verified w/ CheckMe commissioning test.

 

2 Tiers of efficiency rebates: SEER14, EER 12 - $450 SEER 15, EER 12.5 - $550 2 Tiers of efficiency rebates: SEER14, EER 12 - $450 SEER 15, EER 12.5 - $550
Standard Replacement A/C

New A/C system must be sized with approved method; condensing and evaporator units must be matched. Proper installation verified w/ CheckMe commissioning test.

2 Tiers of efficiency rebates:
SEER14, EER 12 - $250 SEER 15, EER 12.5 - $350
2 Tiers of efficiency rebates:
SEER14, EER 12 - $250 SEER 15, EER 12.5 - $350
Heat Pumps;  Existing HP, or Electric Furnace

Call for pre-approval: feasibility of improvement must be evaluated by HEP Efficiency Plus auditor or HEP participating HVAC contractor specializing in Heat Pumps.

N/A $500
Whole House
Fan

New or replacing old non-motorized, non-insulated fan. Fans must have motorized, insulated doors, which shut and seal after every use.

$250
Per household
$250
Per household
Evaporative
Cooler

New evaporative cooler or replacing existing A/C w/ evaporative cooler.
Call for pre-approval of Coolerado

$500 $500
Mechanical Ventilation

Call for pre-approval of HRV, Exhaust Only and Supply Ventilation methods.

20% of cost up to $400 20% of cost up to $400
Replacement Gas Water Heater

Replacing natural draft vented water heater or Electric water heater.
Tier 1 is power vented, not sealed combustion. EF=.62 or >.
Tier 2 is direct vented, sealed combustion, power vented or not. EF= 0.62 or >.
Tier 3 is tankless or tank sealed combustion. Power vented or not. EF = 0.80 or >.

Three tiers of rebates based on venting of water heater: Tier 1, Power Vented- $100 Tier 2, Direct vent- $200 Tier 3, High Efficiency- $400 N/A
Duct Sealing and Insulating

Call for pre-approval: requires Efficiency Audit Plus or participating HEP HVAC duct sealing specialty contractor.

$200 per system N/A
Energy Conservation: Residential